Our new, optimized control system sets new standards in water treatment and filtration for reverse osmosis systems. Equipped with state-of-the-art technology, it enables efficient, precise, and user-friendly monitoring and control of the entire reverse osmosis process – in real time and at the highest technical level.
A key feature is the integrated conductivity meter for continuous monitoring with three selectable measurement ranges: 0–20 μS/cm, 0–200 μS/cm, and 0–2000 μS/cm – ideal for various purity levels and applications.
Leitfähigkeitsmessgerät zur Überwachung und Steuerung von Umkehrosmoseanlagen mit 3 Messbereichen
| Power supply | 230V ±10% 50/60Hz |
|---|---|
| Power consumption | 8.7 VA |
| Ambient temperature | 0–50° |
| Protection rating | IP 54 |
| Protection class | II |
| Conductivity meter |
Deionized water 0–20 µS/cm Permeate: 0–200 µS/cm 0–2000 µS/cm |
| Cell factor |
0.1 to 10.0 can be adjusted in 0.1 increments |
| Dimensions in mm (LxWxH) | 190 x 144 x 120 |
| Panel cutout in mm | 186 x 137 |
| Display | 4x20-character alphanumeric display |
| Display language | German/English |
| Technology | Single-chip microprocessor system |
| Temperature compensation | Optionally adjustable |
| Inputs |
Up to 14 digital inputs Recorder output 10 V Current output 4–20 mA |
| Outputs |
6 relay outputs (normally open, live) rated at 230 V/5 A for solenoid valves and pumps; 3 relay outputs (potential-free, 250 V/5 A) for alarm, deionized water, and permeate |
| Optional | SD card for measurement data collection |